Klixon® C Series: CA, CM, CDA, and CDM
2 to 40 Amp, Commercial, Ignition Protected Thermal Breakers


Ignition protected

The C Series is available in four configurations:
CA: Open construction, automatic reset
CDA: Sealed construction, automatic reset
CM: Open construction, manual reset
CDM: Sealed construction, manual reset

Using a bimetal, snap–acting disc as the sensing and actuating element, the Klixon® C Series thermal circuit breaker provides trouble free over–current protection for harsh environments.


Applications

Accessory and equipment protection for heavy trucks, buses, construction equipment, off–road vehicles, RV’s
Battery protection in electric vehicles


General Envelope Dimensions
Nominal dimensions provided for reference only.

Side View of CA, CM and CDA, CDM (pushbutton omitted on CA and CDA automatic reset versions):

CA, CM and CDA, CDM

Bottom View of CA, CM, CDA, CDM (2–10 Amp configuration):

C series breaker
* * *
Klixon
Thermal Circuit Breakers

Request pricing for this item. We offer a broad array of custom solutions. Click here!

Contact a product specialist.

Request a catalog.

Have a question? Email Klixon now. Click here.



Trip Curve
Approximate Time — Current Characteristics at 77°F (25°C)


Trip Curve Diagram

Dotted Lines: CA, CM, CDA, CDM series (10 Amps and below)
Solid Lines: CA, CM, CDA, CDM series




Derating Curve
Approximate Effect of Ambient Temperature on Ultimate Trip


Diagram: Approximate effect of ambient temperature on ultimate trip
Performance characteristics are based on room temperature (77°F). Consult derating curve at left for ambient temperatures significantly higher or lower than standard room temperature.

Example: At 77°F the device is calibrated to hold at 100% of rated current (1) and trip at 135% of rated current (2). At 140°F, the same device will hold at approximately 78% of rated current (3), and trip at approximately 115% of rated current (4).